2-17
Confidential
Error code E500
An error occurred during access to the DRAM in the main PCB ASSY.
Error code E600
Write error in the EEPROM of the main PCB ASSY
Error code E900
Failed to initialize the NFC module.
Error code EC00
An USB device not within the specifications is connected to the USB terminal, resulting in
overcurrent.
Error code F900
The country code was not entered correctly.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Connection failure of the panel
PCB flat cable
Reconnect the panel PCB flat cable.
2
Panel PCB failure
Replace the panel PCB ASSY.
3
NFC PCB failure
Replace the NFC PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Disconnect the USB device from the USB terminal and turn the machine OFF.
Turn the machine ON again after a while.
• Replace the USB device with a different one.
Step
Cause
Remedy
1
USB host PCB failure
Replace the USB host PCB ASSY.
2
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
The country code was not
entered correctly.
Reenter the country code. (Refer to
Setting by country (function code: 74)" in
Chapter 5.
)
2
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for ImageCenter ADS-2800W
Page 24: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path Front side Back side ...
Page 50: ...3 2 Confidential 2 PACKING ...
Page 53: ...3 5 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Page 54: ...3 6 Confidential 6 OVERVIEW OF GEARS There are no gears to be disassembled ...