4-7
Confidential
1.6
Setting Multi Feeding Sensor Threshold
(1) Connect the machine to your computer using the USB cable in the initial state of
maintenance mode.
(2) Double-click "brADSmt1.exe" that was saved into the computer to start it.
(3) Select the model name in the [Select model:] box, and click the [Start] button. The multi
feeding sensor threshold is set.
(4) Set the sheet for multi feeding sensor threshold setting in the ADF, and execute the
maintenance mode function "Check ADF".
Refer to "1.3.2 ADF performance test (function code: 08)" in Chapter 5.
(5) Execute the maintenance mode function "Acquire white level data and set CIS scan
area".
Refer to "1.3.12 Acquire white level data and set CIS scan area (function code: 55)" in
Chapter 5.
Note:
• For Windows
®
8, right-click "brADSmt1.exe" to display the menu, and select "Run
as an administrator" to start.