2-27
Confidential
4.7
Troubleshooting for Other Problems
4.7.1 Machine does not turn ON
4.7.2 Cannot update firmware
4.7.3 Cannot save data in USB flash memory
4.7.4 USB device connection error
<User Check>
- Check that the power cord or DC plug is connected to the host correctly.
Step
Cause
Remedy
1
Connection failure of the panel PCB
harness
Reconnect the panel PCB harness.
2
Power cord failure
Replace the power cord.
3
AC adapter failure
Replace the AC adapter.
4
Panel PCB failure
Replace the panel PCB ASSY.
5
Panel unit failure
Replace the panel unit.
6
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Make sure that there is no other function running.
Step
Cause
Remedy
1
Firmware version does not match
Install the latest version firmware. (Refer to
.)
2
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Check that the USB flash memory is inserted into the USB terminal correctly.
- Replace the USB flash memory and try saving data again.
- Check that the USB flash memory is not write-protected.
Step
Cause
Remedy
1
Connection failure of the USB host
PCB harness
Reconnect the USB host PCB harness.
2
Panel PCB failure
Replace the panel PCB ASSY.
3
USB host PCB failure
Replace the USB host PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Check that the connected USB device is supported.
- Replace the USB flash memory and try again.
Step
Cause
Remedy
1
Connection failure of the USB host
PCB harness
Reconnect the USB host PCB harness.
2
USB host PCB failure
Replace the USB host PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for ImageCenter ADS-2800W
Page 24: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path Front side Back side ...
Page 50: ...3 2 Confidential 2 PACKING ...
Page 53: ...3 5 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Page 54: ...3 6 Confidential 6 OVERVIEW OF GEARS There are no gears to be disassembled ...