![Brother ImageCenter ADS-2800W Service Manual Download Page 136](http://html.mh-extra.com/html/brother/imagecenter-ads-2800w/imagecenter-ads-2800w_service-manual_55687136.webp)
5-14
Confidential
1.3.12 Acquire white level data and set CIS scan area (function code: 55)
<Function>
This function is used to save the scanning compensation data in EEPROM when the acquired
data is within the standard. When it is not within the standard, it shows error.
<Operating Procedure>
(1) Wipe the first and second side CIS glass four times in the same direction with a cleaning cloth.
(2) Open the front cover and set it on the gray tape of the first side CIS unit so that the white
part of the calibration sheet overlaps with it.
(3) Close the front cover.
(4) Press the [5] key twice in the maintenance mode. "Press START" is displayed on the LCD.
(5) Press the [Start] key.
(6) Once "Clear CS and Press Start Key" is displayed on the LCD, open the front cover and
remove the calibration sheet.
(7) Close the front cover and press the [Start] key. The machine saves the scanning
compensation data to EEPROM and returns to the initial state of maintenance mode.
(8) Wipe the first and second side CIS glass four times in the same direction with a cleaning
cloth again.
(9) Turn OFF the power of the machine to finish it.
Note:
• If any error occurs on this operation, press the [Stop] key and return the machine to the
initial state of maintenance mode. Then refer to the table below and start again from the
procedure (1).
• Even no error is displayed, calibration sheet may be dirty or discolored if something is
wrong on the scanned image after function code 55 was executed. In this case, replace
the calibration sheet with a new one and operate the procedures again from (1).
Error display
Cause
Remedy
No Document
Calibration sheet is not set.
Set the calibration sheet.
Cover is Open
Front cover is open.
Close the front cover properly.
CS ERR U
Dirt on the second side CIS or
calibration sheet
(detected that the data acquired on
the second side CIS was out of
normal range)
Clean the second side CIS or
calibration sheet.
Calibration sheet
Longer side
Summary of Contents for ImageCenter ADS-2800W
Page 24: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path Front side Back side ...
Page 50: ...3 2 Confidential 2 PACKING ...
Page 53: ...3 5 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Page 54: ...3 6 Confidential 6 OVERVIEW OF GEARS There are no gears to be disassembled ...