5-12
Confidential
1.3.10 Change USB No. return value (function code: 45)
<Function>
When the operating system (OS) installed on the computer is Windows Vista
®
, and the
machine is connected to this computer using USB2.0FULL, the OS may not be able to obtain
the USB device serial number depending on the computer and USB device. If the serial
number cannot be obtained, the number of devices increases each time the device is
connected to the computer. To avoid this problem, setting this function to "USBNo.=ON" can
fix the USB No. return value to "0".
The setting currently selected is marked with "*" at the end of the display.
<Operating Procedure>
(1) Press the [4], and then the [5] key in the initial state of maintenance mode. "USBNo." is
displayed on the LCD.
(2) Press the [SET] key. "USBNo.=ON*" is displayed on the LCD.
(3) Press the [
▲
] or [
▼
] key to select "USBNo.=OFF" when fixing the serial number return
value to "0" or "USBNo.=ON" when not fixing it, and press the [SET] key. "Accepted" is
displayed on the LCD, and the machine returns to the initial state of maintenance mode.
(4) Turn OFF the power switch.
LCD
Description
USBNo. = ON
Returns the serial number of the machine. (Default)
USBNo. = OFF
Returns "0".
Note:
• The mode is applied after the power switch is turned OFF and then ON again.
Summary of Contents for ImageCenter ADS-2800W
Page 24: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path Front side Back side ...
Page 50: ...3 2 Confidential 2 PACKING ...
Page 53: ...3 5 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Page 54: ...3 6 Confidential 6 OVERVIEW OF GEARS There are no gears to be disassembled ...