5 - 14
Failure Investigation
for Electronic Parts
LED lamp does not come on
The LED lamp does not light.
Connect it properly.
N
Y
Y
Are the operation PCB assy. and LED
lamp assy. correctly connected?
Connect it properly.
N
Y
Y
Is the LCD (back light PCB assy.)
lead wire correctly connected to the
operation PCB assy.?
Replace the power supply
PCB assy.
N
Is the voltage between pins 4 & 3 at
the power supply PCB assy.
connector 30V DC?
Connect it properly.
N
Are the main PCB assy. and the operation
PCB assy. correctly connected?
Replace the LED lamp assy.
or
Replace the operation PCB assy.
or
Replace the main PCB assy.