5 - 7
E
le
c
tro
n
ic
P
a
rts
Failure Investigation
for Electronic Parts
Main motor does not turn
Y
N
Lower the presser foot lever.
N
Replace the PF switch assy.
From previous page
Replace the main PCB assy.
or
Replace the power supply PCB assy.
or
Replace the main motor.
Are the resistance values for the PF
switch assy. normal?
• PF switch assy. resistance values
When switch is pressed : 1
Ω
or less
When switch is not pressed : 1M
Ω
(In the case of abnormal, when press
the start/stop button, "E1" is displayed.)
Is the presser foot lever down?
Y