2-107
Confidential
■
Error code E600
Error occurred in E2PROM on the main PCB.
<User Check>
- Write the latest firmware.
■
Error code ED00
Communication with the wireless LAN module and main PCB cannot be established upon
startup of the power supply.
■
Error code EE00
After Wireless LAN module and main PCB connection was established at power ON,
communication problem was detected.
■
Error code F900
During function code 74, power is turned OFF.
Print Unable E6
Turn the power off and then back on again.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Print Unable ED
Turn the power off and then back on again.
Step
Cause
Remedy
1
Wireless LAN harness
connection failure
Reconnect the Wireless LAN harness.
2
Main PCB failure
Replace the main PCB ASSY.
Print Unable EE
Turn the power off and then back on again.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Machine Error F9
Summary of Contents for HL-S7000DN Series
Page 176: ...3 8 Confidential 5 LUBRICATION There are no applicable parts ...
Page 181: ...3 13 Confidential 3 Ink Refill Unit Ink refill unit Hook Clamp Hook Hook Hook Engine PCB ASSY ...
Page 245: ...3 77 Confidential 8 Close the Top cover Fig 3 80 Top cover Front ...
Page 356: ...4 13 Confidential Print start position adjustment pattern Fig 4 6 A ...
Page 358: ...4 15 Confidential All patterns Fig 4 7 B C B C A ...
Page 359: ...4 16 Confidential Fig 4 8 D E D E ...
Page 360: ...4 17 Confidential Fig 4 9 G F B C B C ...
Page 421: ...5 33 Confidential ENGN ALL Fig 5 20 ...
Page 422: ...5 34 Confidential MAIN TOP Fig 5 21 ...
Page 423: ...5 35 Confidential MAIN BTM Fig 5 22 ...