2-106
Confidential
■
Error code C700
Memory is insufficient to deploy print data.
<User Check>
- Print by dividing print data.
■
Error code CA00
The overcurrent protection circuit worked when an off-specification USB device was inserted
into the USB host terminal.
<User Check>
- Remove the USB device.
■
Error code E000
An error occurred in the ROM checksum.
<User Check>
- Write the latest firmware.
■
Error code E100
Error occurred in the main PCB program.
<User Check>
- Write the latest firmware.
Out of Memory
Press Cancel.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Unusable Device
Remove the Device. Turn the power off and back on again.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Print Unable E0
Turn the power off and then back on again.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Print Unable E1
Turn the power off and then back on again.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for HL-S7000DN Series
Page 176: ...3 8 Confidential 5 LUBRICATION There are no applicable parts ...
Page 181: ...3 13 Confidential 3 Ink Refill Unit Ink refill unit Hook Clamp Hook Hook Hook Engine PCB ASSY ...
Page 245: ...3 77 Confidential 8 Close the Top cover Fig 3 80 Top cover Front ...
Page 356: ...4 13 Confidential Print start position adjustment pattern Fig 4 6 A ...
Page 358: ...4 15 Confidential All patterns Fig 4 7 B C B C A ...
Page 359: ...4 16 Confidential Fig 4 8 D E D E ...
Page 360: ...4 17 Confidential Fig 4 9 G F B C B C ...
Page 421: ...5 33 Confidential ENGN ALL Fig 5 20 ...
Page 422: ...5 34 Confidential MAIN TOP Fig 5 21 ...
Page 423: ...5 35 Confidential MAIN BTM Fig 5 22 ...