Error code 9801
During 2-sided printing, 2-sided jam sensor detected that the 2-sided tray is not set.
<User Check>
- Install 2-sided tray.
■
Error code 9802
During 2-sided printing, the paper size switching lever of 2-sided tray and paper size from the
driver are not identical.
<User Check>
- Match the paper size switching lever of 2-sided tray with the paper size from the driver.
No DX Tray
Install the duplex tray correctly.
Step
Cause
Remedy
1
2-sided jam sensor harness
connection failure
Reconnect the 2-sided jam sensor
harness.
2
2-sided jam sensor installation
failure
Reinstall the 2-sided jam sensor.
3
Paper feed PCB failure
Replace the paper feed PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
DX Lever Error
Set the Duplex Lever to the correct position according to paper size used.
Step
Cause
Remedy
1
2-sided size sensor harness
connection failure
Reconnect the 2-sided size sensor
harness.
2
2-sided tray failure
Replace the 2-sided tray.
3
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for HL-S7000DN Series
Page 176: ...3 8 Confidential 5 LUBRICATION There are no applicable parts ...
Page 181: ...3 13 Confidential 3 Ink Refill Unit Ink refill unit Hook Clamp Hook Hook Hook Engine PCB ASSY ...
Page 245: ...3 77 Confidential 8 Close the Top cover Fig 3 80 Top cover Front ...
Page 356: ...4 13 Confidential Print start position adjustment pattern Fig 4 6 A ...
Page 358: ...4 15 Confidential All patterns Fig 4 7 B C B C A ...
Page 359: ...4 16 Confidential Fig 4 8 D E D E ...
Page 360: ...4 17 Confidential Fig 4 9 G F B C B C ...
Page 421: ...5 33 Confidential ENGN ALL Fig 5 20 ...
Page 422: ...5 34 Confidential MAIN TOP Fig 5 21 ...
Page 423: ...5 35 Confidential MAIN BTM Fig 5 22 ...