2-36
Confidential
4.
TROUBLESHOOTING
4.1 Error Cause and Remedy
■
Error code 0C01
Time out access request for server due to such reason as wrong server address/network
unconnected/server is not activated.
Error code 0C02
Time out access request for server due to such reason as wrong user name/wrong password/
inconsistency in the date of the machine and server.
Error code 0C03
Time out access request for server due to such reason as wring directory name/no write
authority for directory/write lock on file.
Error code 0C04
Time out access request for user due to such reason as machine watch (RTC) has not been
set and time has not been obtained at SNTP.
<User Check>
- Following the instructions in User’s guide, perform the network setting again.
- Check the network cable.
- Check the network cable for disconnection.
Log Access Error.
Server Timeout, contact your administrator.
Log Access Error.
Authentication Error, contact your administrator.
Log Access Error.
File Access Error, contact your administrator.
Log Access Error.
Wrong Date&Time, contact your administrator.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for HL-S7000DN Series
Page 176: ...3 8 Confidential 5 LUBRICATION There are no applicable parts ...
Page 181: ...3 13 Confidential 3 Ink Refill Unit Ink refill unit Hook Clamp Hook Hook Hook Engine PCB ASSY ...
Page 245: ...3 77 Confidential 8 Close the Top cover Fig 3 80 Top cover Front ...
Page 356: ...4 13 Confidential Print start position adjustment pattern Fig 4 6 A ...
Page 358: ...4 15 Confidential All patterns Fig 4 7 B C B C A ...
Page 359: ...4 16 Confidential Fig 4 8 D E D E ...
Page 360: ...4 17 Confidential Fig 4 9 G F B C B C ...
Page 421: ...5 33 Confidential ENGN ALL Fig 5 20 ...
Page 422: ...5 34 Confidential MAIN TOP Fig 5 21 ...
Page 423: ...5 35 Confidential MAIN BTM Fig 5 22 ...