4-31
Confidential
(5) Press the
Go
button. "LEAK*.**V" is displayed on the LCD. If the voltage shown on the
LCD is within the range from 0.40 to 0.60 V, go to step (6).
If the voltage is outside the range, "Readjust" appears on the LCD. After 2 seconds,
"LEAK*.**V" automatically appears again. Using the volume shown in the figure below,
adjust the voltage so that it becomes within the range from 0.40 to 0.60 V.
Fig. 4-12
(6) Press the
Go
button. "PLZ Power OFF" is displayed on the LCD.
(7) Turn the power OFF and ON.
(8) If you used any box other than the end user’s waste ink box, replace it with the user’s box
waste ink box.
Maintenance drive PCB ASSY
Volume
Summary of Contents for HL-S7000DN Series
Page 176: ...3 8 Confidential 5 LUBRICATION There are no applicable parts ...
Page 181: ...3 13 Confidential 3 Ink Refill Unit Ink refill unit Hook Clamp Hook Hook Hook Engine PCB ASSY ...
Page 245: ...3 77 Confidential 8 Close the Top cover Fig 3 80 Top cover Front ...
Page 356: ...4 13 Confidential Print start position adjustment pattern Fig 4 6 A ...
Page 358: ...4 15 Confidential All patterns Fig 4 7 B C B C A ...
Page 359: ...4 16 Confidential Fig 4 8 D E D E ...
Page 360: ...4 17 Confidential Fig 4 9 G F B C B C ...
Page 421: ...5 33 Confidential ENGN ALL Fig 5 20 ...
Page 422: ...5 34 Confidential MAIN TOP Fig 5 21 ...
Page 423: ...5 35 Confidential MAIN BTM Fig 5 22 ...