4. FUNCTION SETTINGS
KE-430HX/KE-430HS, BE-438HX/BE-438HS
21
Device settings (500
−
599)
No.
Setting range
Initial value
Setting units
Setting details
500 ON/OFF
OFF
-
Thread nipper operation
ON: Enabled
* However, all of the following conditions must be
satisfied.
Memory switch No. 100 = ON
Memory switch No. 566 = ON
Slow start speed is 8 or 9
Sewing speed is 1500 sti/min. or more
OFF: Disabled
550
OFF,
100
−
2000
(ms)
OFF 100
Output continue time for needle cooler device when sewing
machine is stopped
OFF: Needle cooler device is not used
100 to 2000: Output is continued for the specified time.
551
OFF, 1
−
3
(stitches)
430H-05: 1
1
Upper thread tension release at the sewing start
* Only enabled when the thread nipper is not operating.
OFF: Not released
1 to 3: Released during the specified number of stitches.
OFF
554 ON/OFF
OFF
-
Use of the thread breakage sensor (available by special order)
ON: Used
OFF: Not used
555 ON/OFF
OFF
-
Sewing start sensing sensitivity for thread breakage sensor
(available by special order)
ON: 10 stitches at sewing start
OFF: 5 stitches at sewing start
565
*1
0
−
2
0
1
Tension release solenoid power setting
0: Standard
1: Greater force
2: Maximum
566
*2
ON/OFF
430H-01: ON
-
Thread nipper device installation
ON: Installed
* The thread nipper device only operates when all of the
following conditions are satisfied.
Memory switch No. 100 = ON
Memory switch No. 500 = ON
Slow start speed is 8 or 9
Sewing speed is 1500 sti/min. or more
OFF: Not installed
NOTE:
If the thread nipper device is installed, do not set this to
“OFF”. If this is not observed, damage may occur.
430H-03: ON
430H-05: OFF
430H-0K: ON
438H: OFF
567 ON/OFF
OFF
-
Upper thread tension during feeding while upper shaft is
stopped
ON: Not released
OFF: Released
580
-80
−
115
(degrees)
10 5
Nip timing offset for thread nipper device
581
-160
−
110
(degrees)
-110 5
Release timing offset for thread nipper device
*1: This is not displayed for models with digital tension.
*2: This is not initialized during initialization mode.
Summary of Contents for BE-438HS
Page 203: ...14 ELECTRIC MECHANISM 192 KE 430HX KE 430HS BE 438HX BE 438HS 4313B ...
Page 204: ...14 ELECTRIC MECHANISM 193 KE 430HX KE 430HS BE 438HX BE 438HS 4314B ...
Page 205: ...14 ELECTRIC MECHANISM 194 KE 430HX KE 430HS BE 438HX BE 438HS 4315B ...
Page 206: ...14 ELECTRIC MECHANISM 195 KE 430HX KE 430HS BE 438HX BE 438HS 4316B ...