Brooks
®
Model SLA5840
1-3
Section 1 Introduction
Installation and Operation Manual
X-PR-SLA5840-Series-RevB-RT-eng
Part Number: 541B201AAG
October, 2017
Table 1-1 SLA5840 Flow Ranges and Pressure Ratings
Table 1-2 SLA5840 Series Specifications
Pressure Controller
Pressure Controller
Pressure Controller
Pressure Controller
Pressure Controller
Pressure Controller
Pressure Controller
Pressure Controller
Pressure Controller
Pressure Controller
Flow Ranges
Flow Ranges
Flow Ranges
Flow Ranges
Flow Ranges
Minimum
Minimum
Minimum
Minimum
Minimum
Maximum
Maximum
Maximum
Maximum
Maximum
Pressure Equipment
Pressure Equipment
Pressure Equipment
Pressure Equipment
Pressure Equipment
Model
Model
Model
Model
Model
Control Mode
Control Mode
Control Mode
Control Mode
Control Mode N2 Eq. Ratings (lpm)
N2 Eq. Ratings (lpm)
N2 Eq. Ratings (lpm)
N2 Eq. Ratings (lpm)
N2 Eq. Ratings (lpm)
Full Scale Pressure
Full Scale Pressure
Full Scale Pressure
Full Scale Pressure
Full Scale Pressure
Full Scale Pressure
Full Scale Pressure
Full Scale Pressure
Full Scale Pressure
Full Scale Pressure
Directive (PED)
Directive (PED)
Directive (PED)
Directive (PED)
Directive (PED)
Min. F.S.
Min. F.S.
Min. F.S.
Min. F.S.
Min. F.S.
Max. F.S.
Max. F.S.
Max. F.S.
Max. F.S.
Max. F.S.
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Module H Category
Module H Category
Module H Category
Module H Category
Module H Category
SLA5840
Remote Transducer
0.003
50
10 psi
1500 psia/103 bara
Sound Engineering
Upstream or Downstream
0.1
10
1500 psi
4500 psia/310 bara
Practices (SEP)
*Alarm modes are dependent on the communications interface. These are described in the corresponding digital communication interface manual.
Performance
Performance
Performance
Performance
Performance
Pressure Accuracy
Pressure Accuracy
Pressure Accuracy
Pressure Accuracy
Pressure Accuracy
Dependent on Remote Pressure Transducer
(Including Linearity and Hysteresis)
(Including Linearity and Hysteresis)
(Including Linearity and Hysteresis)
(Including Linearity and Hysteresis)
(Including Linearity and Hysteresis)
Flow Accuracy (N2 equivalent)
Flow Accuracy (N2 equivalent)
Flow Accuracy (N2 equivalent)
Flow Accuracy (N2 equivalent)
Flow Accuracy (N2 equivalent)
±0.9% of S.P. (20-100% F.S.)
+0.18% of F.S. (2-20% F.S., 1-20% F.S. from 1-50 lpm)
Control Range
Control Range
Control Range
Control Range
Control Range
20:1 Typical - Application specific
Repeatability & Reproducibility
Repeatability & Reproducibility
Repeatability & Reproducibility
Repeatability & Reproducibility
Repeatability & Reproducibility
0.20% S.P.
Linearity
Linearity
Linearity
Linearity
Linearity
Included in accuracy
Response Time (
Response Time (
Response Time (
Response Time (
Response Time (Settling time within
Settling time within
Settling time within
Settling time within
Settling time within
<1 second
±2% F.S. for 0-100% command step)
±2% F.S. for 0-100% command step)
±2% F.S. for 0-100% command step)
±2% F.S. for 0-100% command step)
±2% F.S. for 0-100% command step)
Zero Stability
Zero Stability
Zero Stability
Zero Stability
Zero Stability
Dependent on Remote Pressure Transducer
Temperature Coefficient
Temperature Coefficient
Temperature Coefficient
Temperature Coefficient
Temperature Coefficient
Dependent on Remote Pressure Transducer
Pressure Coefficient
Pressure Coefficient
Pressure Coefficient
Pressure Coefficient
Pressure Coefficient
±0.03% per psi (0-200 psi N2)
(Flow Measurement Only)
(Flow Measurement Only)
(Flow Measurement Only)
(Flow Measurement Only)
(Flow Measurement Only)
Attitude Sensitivity
Attitude Sensitivity
Attitude Sensitivity
Attitude Sensitivity
Attitude Sensitivity
The accuracy of the Pressure Sensor is not attitude dependent
Ratings
Ratings
Ratings
Ratings
Ratings
Operating Temperature Range
Operating Temperature Range
Operating Temperature Range
Operating Temperature Range
Operating Temperature Range
-14 to 65
o
C (7 to 149
o
F)
Transducer Pressure Ratings
Transducer Pressure Ratings
Transducer Pressure Ratings
Transducer Pressure Ratings
Transducer Pressure Ratings
Dependent on Remote Pressure Transducer
Leak Integrity (external)
Leak Integrity (external)
Leak Integrity (external)
Leak Integrity (external)
Leak Integrity (external)
1x10
-9
atm. cc/sec He
Mechanical
Mechanical
Mechanical
Mechanical
Mechanical
Valve Type
Valve Type
Valve Type
Valve Type
Valve Type
Normally Closed, Normally Open
Primary Wetted Materials
Primary Wetted Materials
Primary Wetted Materials
Primary Wetted Materials
Primary Wetted Materials
316L Stainless Steel, High Alloy Stainless Steel, Viton
®
fluoroelastomers.
Optional Buna-N, Kalrez
®
, Teflon
®
/Kalrez
®
, and EPDM
Diagnostics
Diagnostics
Diagnostics
Diagnostics
Diagnostics
Status Lights
Status Lights
Status Lights
Status Lights
Status Lights
MFC Health, Network Status
Alarms*
Alarms*
Alarms*
Alarms*
Alarms*
Sensor Output, Control Valve Output, Over Temperature, Power Surge/Sag, Network Interruption
Diagnostic/Service Port
Diagnostic/Service Port
Diagnostic/Service Port
Diagnostic/Service Port
Diagnostic/Service Port
RS485 via 2.5 mm jack (Located under the top cover in SLAMf version)
SLA5840
SLA5840
SLA5840
SLA5840
SLA5840