11-6
PRESSURE SYSTEM TIPS
DO NOT attempt to tighten, repair or replace any fitting, line or compo-
nent when there is pressure in the cooking well. Hot oil could spray out
under pressure causing serious burns.
COMPLAINT
CAUSE
REMEDY
No pressure
1.
Pressure regulating valve
OPEN
2.
Pressure regulating valve
dirty or blocked open
3.
Leaks around cover
O-ring
1.
CLOSE.
2.
Contact service person.
3.
Replace O-ring.
Excess pressure
1.
Turn cook/filter switch OFF.
Contact service person.
broaster.com Manual #15459 5/02 Rev: 3/16A