5–3
2400GH LIGHTING INSTRUCTIONS
Start Up
1.
Turn cook/filter switch OFF.
2.
See OIL LEVEL.
3.
Turn gas shut-off valve (1) ON. Wait
five minutes before turning gas control
ON.
4.
Slide switch (2) on top of gas control
to ON.
*
The model 2400GH has an
intermittent pilot burner.
This type of pilot lights when the control-
ler calls for heat and goes out when the
controller is not calling for heat.
5.
To light pilot and main burners, turn
cook/filter switch to COOK.
*.
Shut Down
1.
Turn cook/filter switch OFF.
2.
Turn gas control switch (2) OFF. *
3.
Turn gas shut-off valve (1) OFF.
broaster.com Manual #15459 5/02 Rev: 2/14
* This switch is not used on gas pressure fryers manufactured for use in the European Union.