Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 42
Broadcom Confidential and Proprietary
value = 2
: Selecting 10FD
value = 3
: Selecting 100HD
value = 4
: Selecting 100FD
Example:
b57diag –mbas 0
: To select Auto speed mode.
-disableeswitch
Disable E-Switch.
Act like engineering mode "eswitch -f" command. Disable the E-Switch on the device that
support eswitch, such as 5756. Without this option, PHY loopback test, external loopback
test (pkttest -e), and carrier test are performed on both laptop mode and docking mode. With
this option, above tests are performed on the default port.
-h
: High Resolution (80x50) Video Mode
-p
: Print on error
-q
: Quick diagnostic mode
-asf <value>
: Enable/Disable (value = 1/0) ASF in manufacture mode
-ipmi <value> : Enable/Disable (value = 1/0) IPMI in manufacture mode
-com <value> : enable com port, value(1..4)
-errctrl <c>
: On Error -> a:abort w:wait l:loop c:cont s:skip
-ems <size>
: Enter external memory size in HEX to test
-findref
: Detect reference device
-lbm <n>
: Option to set mac loopback packets
-lbp <n>
: Option to set phy loopback packets
-lbe <n:n:n> : Option to set external loopback packets, Format:
<1000Mbps:100Mbps:10Mbps>
-npol
: Select Negative Link Polarity in TBI test
-ref
: Run test with reference device
-fail2
: On failure offset the failed message printout
-ctpm
: Clears TPM data stored in NVRAM
-optmem : Option to allocate memory for optimization .
( For use with DOS B57diag on an EFI BIOS).
-
rc <filename> : Specify a script file to source after starting b57diag.