53-1004105-13 Hardware Installation Guide
Brocade X6-8 Director
Hardware Installation Guide
Model
Port Type
Number of Ports
Description
10GbE
512
Up to 512 10GbE ports supported with 8 FC32-64 port blades for FCoE
applications. The 256 ports are provided by 16 40GbE transceivers installed
on each blade operating in 4x10 breakout mode.
40GbE
8
Up to 8 40GbE ports supported with 4 SX6 extension blades.
10GbE
64
Up to 64 10GbE ports supported with 4 SX6 extension blades.
1GbE
64
Up to 64 1GbE ports supported with 4 SX6 extension blades.
Class 1M Transceiver Specifications
Specification
Standards Approval
Description
Class 1M
Pass
Radiation output and standards information
< 3.1 mW
N/A
Max output of laser radiation
N/A
N/A
Pulse duration
840–860 nm
N/A
Emitted wavelength
IEC 60825-1:2007
IEC 60825-2:A2/2010
Pass
The name and publication date of the
standard
Serial Port Specifications (Pinout RJ-45)
Pin Number
Signal
Description
1
Not supported
N/A
2
Not supported
N/A
3
UART1_RXD
Receive data
4
GND
Logic ground
5
GND
Logic ground
6
UART1_TXD
Transmit data
7
Not supported
N/A
8
Not supported
N/A
Serial Port Specifications (Protocol)
Parameter
Value
Baud
9600
Data bits
8
Parity
None
Flow control
None
Flow control is disabled on customer terminal servers.