53-1004105-13 Hardware Installation Guide
Brocade X6-8 Director
Hardware Installation Guide
•
Sensor ID (an index number)
•
Slot number
•
Sensor index (when command issued with the
--detail
option)
•
Sensor state (OK or absent)
•
Temperature in both Centigrade and Fahrenheit
The following is an example of
tempShow
output:
chassisX6-8:admin> tempshow
Sensor Slot Sensor State Centigrade Fahrenheit
ID Index
===================================================================
1 3 0 Ok 30 86
2 3 1 Ok 53 127
3 4 0 Ok 31 87
4 4 1 Ok 50 122
5 5 0 Ok 29 84
6 5 1 Ok 29 84
(output truncated)
Note the following facts about this output:
•
The absent state simply reflects that the blade slot is empty.
•
The sensor index is mainly for support use.
•
Multiple sensors are commonly averaged to determine thresholds used for managing fan speeds or for determining a
high temperature condition that may require that the blade be shut off.
Running Diagnostic Tests
Diagnostic tests are automatically run during POST to check the status of the device. Any error messages generated
during POST are sent to the error logs and to the serial console if the console is connected.
Diagnostic tests can also be run manually to test and troubleshoot the hardware and the firmware, including internal
connections and circuitry, transceivers, and port cables. However, diagnostic tests are generally intended for use by
support personnel.
NOTE
Error messages do not necessarily indicate that the device requires maintenance.
Each diagnostic test can be implemented by entering the related command through a telnet or serial session. For a list of
diagnostic tests and commands, refer to the
Brocade Fabric OS Administration Guide
.
All diagnostic tests are run at all supported link speeds. They might temporarily lock the transmit and receive speeds to
a specific speed. Some diagnostic tests require interconnecting the ports to each other or using loopback plugs. If ports
are interconnected, the media (cables and transceivers) at each end of the connection must be of the same type. For
example, short-wavelength media must be connected to short-wavelength media, and likewise, long-wavelength media
must be connected to long-wavelength media and copper media must be connected to copper media.
For more information about diagnostic tests and how to run them, refer to the
Brocade Fabric OS Administration Guide
and the
Brocade Fabric OS Command Reference Manual
. For information about system error messages (
errShow
or
errDump
), refer to the
Brocade Fabric OS Troubleshooting and Diagnostics Guide
.
53-1004105-13
94