AIRCRAFT FLIGHT
MANUAL
BRISTELL B23
Document No.: ADXC-73-001-AFM
Non-approved page
Revision: A2
1-6
Date of Issue: 15.04.2021
Light
Display
Condition
Implication/ Procedure
cont...
AMB.
EMS
master
caution
Electric system
voltage below 11
Volt
Check ALT1/ALT2 ON
Check AMP positive (charging
the system)
USB power - remove load
switch off all non-essential
electrical equipment
Battery current
below -10 Amp
(discharge)
Observe; if continuous:
Check ALT1/ALT2 ON
Check AMP positive (charging
the system)
USB power - remove load
switch off all non-essential
electrical equipment
Battery current
above +10Amp
(charge)
Observe; if continuous:
MASTER Switch OFF
Alternator 1 does
not deliver
Switch ALT 1 ON,
Check ALT 1 and ALT 1 CTRL
CB
If the caution indication
persists: ALT 1 OFF
Alternator 2 does
not deliver
Switch ALT 2 ON,
Check ALT 2 and ALT 2 CTRL
CB
If the caution indication
persists: ALT 2 OFF
Back Up Batt supply
insufficient (below
11 Volt)
Check system voltage, if low
consider 3.8.5 Alternator
failure / use of back-up battery
BACKUP BATT
VOLTS
AMPS
AMPS
ALT 1
ALT 2