Document: SLSA-MIP-5-4-0-US
Date of Issue: 05/2016
Revision: -
6-11
6.3.7
Installation of the trim tab control actuator
Type of maintenance: heavy
Authorization to perform:
LSA mechanic or A&P mechanic (Airframe and Power plant)
Tools needed:
wrench size 5
screwdriver
pliers
Insert trim tab actuator (6) in to the elevator or aileron through access hole (2).
Connect the actuator (6) from the elevator or aileron skin.
Connect the rod end (4) with the trim tab lever (5).
Connect the actuator wires (3).
Check correct trim tab operation and adjustment of trim tab deflections
(see 6.4.3.5).
Close the access hole with cover (1).
6.3.8
Removal of aileron control lever behind main center wing spar
Type of maintenance: heavy
Authorization to perform:
LSA mechanic or A&P mechanic (Airframe and Power plant)
Tools needed:
wrench size 7/16 in
Remove access hole cover on bottom skin.
Disconnect both push rods (5) from the control lever (1) (see Fig. 6-10).
Disconnect the control lever
– unscrew the nut.
Remove control lever from the bolt (4).
6.3.9
Installation of aileron control lever behind main center wing spar
Type of maintenance: heavy
Authorization to perform:
LSA mechanic or A&P mechanic (Airframe and Power plant)
Tools needed:
wrench size 7/16 in
Insert the control lever (1) on the bushing (3) (see Fig. 6-10).
Connect the nut (2) on bolt (4).
Connect control push rod (5) with control lever.
Close access hole cover.
Summary of Contents for S-LSA