Air 70 Rev. D
35
Chapter 13 ErP-values
&ODVVL¿FDWLRQIURP-DQXDU\
SEC Class („Average climate“)
SEC in kWh/m²/a
$KLJKHVWHI¿FLHQF\
SEC < -42
A
6(&
B
6(&
C
6(&
D
6(&
E
OHVVHI¿FLHQF\
6(&
Productdatasheet conform Ecodesign (EU), nr. 1254/2014 (Annex IV)
Supplier:
Brink Climate Systems B.V.
Model:
Air 70 (Plus)
Climate zone
Type of control
SEC-Value
in kWh/m²/a
Type of
control
The annual electricity
consumption
(AEC) in kWh
The annual heating saved
(AHS) in kWhT
Average
Manual switch
-34,31
A
321
4116
Local demand control with sensor
-40,16
A
224
4371
Cold
Manual switch
-74,13
A+
858
8052
Local demand control with sensor
-82,45
A+
761
8550
Warm
Manual switch
-11,49
E
276
1861
Local demand control with sensor
-19,94
E
179
1976
Type of ventilation unit:
Ventilation unit with heat recovery
Fan
Variable speed EC fan
Type of heat exchanger:
5HFXSHUDWLYHSODVWLFFURVVFRXQWHUÀRZKHDWH[FKDQJHU
7KHUPDOHI¿FLHQF\
79%
7KHUPDOHI¿FLHQF\
73%
0D[LPXPÀRZUDWH
70 m³/h
Electric power input:
29 W
Sound power level Lwa:
G%$
5HIHUHQFHÀRZUDWH
49 m³/h
Reference pressure difference:
0 Pa
6SHFL¿F3RZHU,QSXW6(/
0,2 W/m³/h
Control factor:
1,0 in combination with manual switch
0,65 in combination with local demand control with sensor
/HDNDJH
Internal
3,9%
External
0,3%
3RVLWLRQ¿OWHUZDUQLQJ
Through LED indicator on the appliance/ On the Manual switc (led)
Attention!
)RURSWLPDOHQHUJ\HI¿FLHQF\DQGDSURSHURSHUDWLRQDUHJXODU¿OWHULQVSHFWLRQ
cleaning or replacement is necessary.
Internet address for Assembly instructions:
http://www.brinkclimatesystems.nl/installateurs/kenniscentrum/Documentatie.aspx
6HQVLWLYLW\WRDLUSUHVVXUHÀXFWXDWLRQV
9,0%
$LUWLJKWQHVVEHWZHHQLQGRRU RXWGRRU
6,9%
Bypass:
<HVZLWK%\SDVV
* Measurements executed by TZWL according to the EN 13141-8 standard (TZWL-report M.84.09.204.AK, February 2016).
** Measurements executed by Peutz (Peutz report A3032-1-RA-001, February 2016) at 70% 0f 55 m
3
/h.