28
Air 70 Rev. D
X9
Chapter 10 Electric connections accessories
A = Air 70
B = Plus pcb
C = Control pcb
D = CO
2
VHQVRU¿[ZLWKVFUHZRQWKHLQGLFDWHGSRVLWLRQLQWKH
appliance
E = Cable supplied with CO
2
sensor; Connect the connector
mounted on the cable to pcb connection X9
F = Set dipswitch on control pcb for CO
2
sensor; set dipswitch
2 to ON
10.4 Connecting CO
2
sensor (only possible with Plus pcb)
E
F
230V
50Hz
B
A
D
X9
F
Plus pcb
ON
1
2
3
4
CO
2
-sensor
C
The CO
2
control system only works when the Air 70 is set to ventilation mode 1 or 2. If the CO
2
sensor measures
an increase of the CO
2
value, the ventilation capacity is automatically increased. When the CO
2
value decreases,
the ventilation capacity will automatically be reduced again (see pictures). The factory setting (default) of the ven-
tilation modes and the CO
2
value can be changed with the aid of the Brink service tool, see §13.1.
15 m
3
/h (default)
40 m
3
/h (default)
400 ppm
(default)
1200 ppm
(default)
Ventilation mode 1
25 m
3
/h (default)
55 m
3
/h (default)
400 ppm
(default)
1200 ppm
(default)
Ventilation mode 2
X12
10.5 Connecting
external switch
(only possible for Plus pcb)
A = Air 70
An On/Off switch can be connected to terminal X12.
When the contact closes, the fan stops. This is can be
XVHGIRULQVWDQFHZKHQD¿UHSODFHLVOLJKWH
230V
50Hz
X12
A
brown
green
white
yellow