Air 70 Rev. D
13
An optional 4-way switch is connected to the modular connec-
tor type RJ12; connection X13 to plus pcb. This connector is
accessible after removing the front cover (see respectively
§8.1 item 2).
If a 4-way switch is connected, the settings according to the
table below will be linked to the ventilation modes of the Air
70. The current ventilation mode can only be changed with the
push buttons on the appliance when the switch is on setting 1.
7KH$LUXVHVWKHH%XVSURWRFRO7KH3OXVSFELV¿WWHGZLWK
two 2-pole (detachable) screw connectors X14 and X15 for
making the eBus connection.
The eBus protocol may for instance be used to link (cascade
control) appliances (see §10.8). Because of polarity sensitiv-
ity, always connect contacts X1-1 to X1-1 and contacts X1-2
to X1-2; the appliance will not work when these contacts are
interchanged.
Control pcb
Plus pcb
Control pcb
Plus pcb
eBus connector X14/
X15 on Plus pcb
modular connector X13
on Plus pcb
Chapter 5 Installation
Warning
The preheater and the Control pcb carry 230 V.
Always take the voltage from the appliance by
pulling the mains plug when working on the ap-
pliance.
5.5 Electric
connections
5.5.3 Connecting the eBus connector (only possible for Plus version)
5.5.2 Connecting the optional multiple switch (only possible for Plus version)
5.5.1 Connecting the power plug
The appliance can be connected to an easily accessible,
earthed wall socket with the plug that is mounted to the ap-
pliance. The electric installation must comply with the require-
ments of your power company.
Make allowance for the 175 W preheater.
Refer to diagrams §10.3.1 to §10.3.2 for connection examples
multiple switch.
Position
4-way switch
Ventilation mode Air 70
1
1
2
3
3
5
* Setting 1 of the 4-way switch is a non-switched setting (cur-
rent ventilation mode = setting as per appliance).