Air 70 Rev. D
Chapter 5 Installation
There are two ways required the hole for mounting appli-
ance can be drilled in the wall, namely:
A hole with a diameter of Ø280 mm at right angles
through the wall,
A hole with a diameter of Ø260 mm at an angle of 3 °.
WALL THICKNESS BETWEEN 500 MM AND 600 MM
(with wall thickness between 300 mm and 500 mm go to
point 3)
Ø280 mm
2b
3°
Y
5.4 Installation sequence
90°
Cut wall sleeve at length X.
X = Y + 34 mm
Example
Wall thickness = 535 mm
Cut length = 535 + 34 = 569 mm
x
90°
Before you start drilling verify the presence of pipes
in the wall!
Ø260 mm
93°
Be careful when drilling to prevent the hole in the
inner wall to prevent outbreak of pieces from wall /
plaster!
Hole of Ø280 mm
drilling at right angle
Hole of Ø260 mm at a angle of 3°
1
2
2a
MOUNTING WALL SLEEVE AND EXTERIOR COVER
DRILL HOLE IN WALL
Wedges
(These are not required if the hole in the
wall has already been drilled at a pitch!)
Wall sleeve to be
sealed all around
using moisture-
resistant sealant.
Ø
260 mm
Y
Exterior
wall
Ø
280 mm
Y
Exterior
wall
Align the wall sleeve with separating wall.
separating wall
wall sleeve
Aligning here!
Locate wall sleeve at top
of drilled hole!
Exterior wall
Separating
wall
0 mm