Empty Tank Alarm
This alarm is triggered when the pH solution tank is (almost) empty. It is necessary to
replace or refill the tank. If the alarm goes off when the tank is not empty check if the
buoy is fixed and placed in a perfectly vertical position.
8.6.3
pH Timeout Alarm
This alarm is triggered if the compensation is not having the right effect during the
predefined period. If the pH reading is not sufficiently corrected, within the predefined
time (120 min by default), once the pH compensation has begun, then the equipment
will switch off the dosing pump and will trigger the alarm. This alarm will therefore
indicate that either the pH sensor is not reading properly, or that the predefined
period necessary for compensation to occur (depends on the pool volume) is not
enough.
In case you see this alarm, please contact Bright Blue or a qualified technician.
9
Terms and Conditions
9.1
Copyright
The present User Manual contains information secured by copyright. Every right is
reserved to
Bright Blue, Lda
.
This User Manual has been written for personal use. The copy, reproduction or
translation of the present document, as a whole or partially, requires prior written
consent from
Bright Blue, Lda
.
9.2
Responsibilities
This User Manual has been written to be read, understood and followed by the people
responsible for the installation, operation and maintenance of
SANUS
models.
Knowledge of this manual’s contents is vital to prevent damage and for correct system
operation. It is intended to familiarize the user with the equipment and illustrate its
mode of operation in order to obtain the maximum system profitability possible.
This User Manual contains important security information. Following the given
instructions will contribute to:
•
prevent possible hazards
•
reduce equipment failure
•
reduce repair costs
•
increase reliability and life span of the equipment and accessories
This User Manual contains the necessary instructions to prevent environmental
hazards and rules to sustain environmental protection. It should be kept close to the
Summary of Contents for SANUS
Page 1: ...SANUS CONTROLADOR DE PH PH CONTROLER Espa ol 17 Portugu s 3 English 29...
Page 2: ......
Page 45: ......