©Copyright 2010 BRIGHT BLUE, LDA
32
V2016
The information in this document might be changed without previous notice
5
Operation
In this chapter details the system’s handling, operation and necessary adjustments.
The SANUS pH controller measures the water pH and acts to compensate it when the
values are out of the defined range. The compensation can be activated or deactivated
by the user through the menu ON/OFF.
The parameter regulation is done in the SETUP menu, where the user can define a pH
reference value (set-point), the type of compensation liquid (acid/base) and the
compensation and alarm triggers. When the SETUP and the CALIBRATION menus the
system enters automatically in standby.
This equipment will only operate when the circulation pump is on.
5.1
Front Panel
Figure 14 – Front Panel
Item
Function
1
2 line screen with 16 characters that provides information and allows
interaction with the equipment
2
Round command button for navigation and setup actions when pressed:
•
Left rotation allows menu change and decrease in one unit within a
submenu;
•
Right rotation allows menu change and increase in one unit within a
submenu;
•
Button pressing enters a submenu or accepts the set values;