Service & Troubleshooting Guide - Home Generator System - Models 040213 & 040234 (15kW)
Section 3 - Unit Disassembly Information
Page 55
3
Disconnect Fuel Solenoid
1. Remove
wire #14
(Fig. 54
) from solenoid.
Fig. 54 - Disconnecting Fuel Solenoid
2. Gather the wires from the fuel solenoid and the
battery and feed them through the bulkhead
grommet (Fig. 55).
Fig. 55 - Battery Harness Grommet
3. Disconnect the fuel supply hose.
Fig. 56 - Disconnect Fuel Hose
NOTE
: Cover openings in hose and regulator to
prevent foreign material from entering
equipment.
4. Remove the two bolts (
Fig. 57) that secure the
mounting bracket for the solenoid/regulator
assembly.
Fig. 57 - Regulator Mounting Bolts
5. Remove the assembly and set aside.
The control panel bulkhead is now secured to the base
of the standby generator with the remaining bolts
(Fig.58).
Fig. 58 - Control Panel Bulkhead Fasteners
Summary of Contents for 40213
Page 3: ...Page 3...
Page 4: ...Page 4...