Brew-Boss® V2.06 Operation Manual
Connect Heating Element to the Controller
The heating element simply plugs into the controller using the L6-30 twist lock connectors. Make sure
that the controller is
NOT
plugged into the 120 or 240VAC source and the switch on the front of the
controller is in the “
OFF”
position. It is possible that one could touch one of the metal prongs while
plugging the two connectors together, so make sure the POWER IS OFF! This plug is provided to
make it easy to detach the kettle from the controller so the kettle can be cleaned. Make sure to always
POWER OFF the controller and unplug the controller from the 120 and/or 240VAC source when
unplugging or plugging in the heating element assembly/assemblies.
The heater element should be plugged into the controller before the controller is powered up. Care
should be taken when removing the cord from the heating element to assure that the twist lock is
released by turning counter clockwise before pulling. The cord should come off easily, do not force the
cord off or damage could result to the prongs on the heater element.
Turn the Master Switch On
To turn the master switch on the front of the controller on, move the red lever switch on the front of the
controller to the
“ON”
position. You can use this switch as an emergency stop switch for the heater if
for some reason you need to turn the heater off quickly, like when you inadvertently turn the heater on
without water! Upon power-up, the LCD on the controller will display a start-up message “B-BOSS
X-X” where the “X-X” is the version number of the firmware installed. If you forgot to plug in the
temperature probe, the controller will beep and warn you that no temperature probe was detected. The
Wi-Fi radio in the controller takes 20-45 seconds to start up. Wait at least this time before trying to
connect to it with the tablet.