➋
S
WITCHING FROM
TOWNGAS
TO
LPG GAS
FOR SINGAPORE
/I
N
DONESIA
.
• Using a small flat-head screwdriver,
screw in the brass burner-power screws
(yellow)
all the way
, (fig. 01)
screwing
them in a clockwise direction.
• Replace the gaskets and the knobs,
paying careful attention to their direction
and ensuring that the knobs are pushed in
all the way.
• Put the burner heads, covers and pan
supports back in position.
C
hanging the type of gas
Installing your hob in all simplicity
Tap axis
Adjustment screw
Fig. 1
14
Appliance designed for installation
LPG
in
SINGAPORE/INDONESIA
G30
Hourly input -see below at 15°C at 1013 mbar
30 mbar
E
XTRA FAST BURNER
Indicator marked on injector
88A
Nominal heat rating
(kW)
3.15
Low heat rating
(kW)
0.830
Hourly output
(l/h)
229
S
EMI
-
FAST BURNER
Indicator marked on injector
62
Nominal heat rating
(kW)
1.50
Low heat rating
(kW)
0.620
Hourly output
(l/h)
109
30 cm hob 2 gas rings
Total nominal heat rating
(kW)
4.65
Maximum output
(l/h)
338
●
Gas rating
MARK ON THE INJECTORS
This table shows the position of the injectors on your hob
depending on the type of gas you use. The number is
marked on each injector.
NATURAL GAS
S
INGAPORE
/I
NDONESIA
137
94
Summary of Contents for TG1120B
Page 1: ...EN GUIDE FOR INSTALLATION AND USE Cooking hob...
Page 19: ...19...