13
❷
S
W I T C H I N G
F R O M
TOWNGAS
T O
NATURAL GAS
FOR CHINA OR SINGAPORE
.
A
DJUST THE RETARDER
/
ON THE TAPS
located under the knobs. Proceed as
follows:
• Work on one tap at a time.
• Pull off all knobs and sealing rings.
• Using a small screwdriver, turn the
adjustment screw
clockwise
until it
reaches the lowest possible setting that
does not extinguish the flame.
• Check the position of the sealing rings
and knobs.
• Replace the sealing rings and knobs.
• Put the burner heads, covers and pan
supports back in position.
C
hanging the type of gas
Installing your hob in all simplicity
Tap axis
Adjustment screw
Fig. 1
Appliance designed for installation
NATURAL GAS
in
CHINA or SINGAPORE
G20
Hourly input -see below at 15°C at 1013 mbar
20 mbar
E
XTRA FAST BURNER
Indicator marked on injector
137
Nominal heat rating
(kW)
3.10
Low heat rating
(kW)
0.870
Hourly output
(l/h)
295
S
EMI
-
FAST BURNER
Indicator marked on injector
94
Nominal heat rating
(kW)
1.50
Low heat rating
(kW)
0.615
Hourly output
(l/h)
143
30 cm hob 2 gas rings
Total nominal heat rating
(kW)
4.60
Maximum output
(l/h)
438
●
Gas rating
MARK ON THE INJECTORS
This table shows the position of the injectors on your hob
depending on the type of gas you use. The number is
marked on each injector.
NATURAL GAS
C
HINA
OR
S
INGAPORE
137
94