RS232 Port
PSI BOX Reference
The RS232 DIP Switches.
______________________
DIP switches 1-7 on switch block 2 are used to set the all
the RS232 options. These options include baud rate, handshake
type, parity options and data word length.
The DIP switches are only read when the PSI BOX is
powered up. Changing the DIP switch setting whilst the PSI
BOX is running will have no effect.
Setting The Baud Rate.
____________________
DIP switches 1-3 on switch block 2 are used to set the
RS232 baud rate. The range of baud rates is 75 - 19200 baud.
Figure 5-3. Baud Rate Settings.
___________________________
1-3 Baud Rate
ÚÄÅÄ¿
³
³
³
å
on
ÚÄÄÄÄÄÄÄÄ¿
³äääããããã³
æ
off
³
12345678
³
ÀÄÄÄÄÄÄÄÄÙ
DIP 1
DIP 2
DIP 3
BAUD RATE SET
_____
_____
_____
_____________
0=Off
0
0
75 BAUD
1=On
0
0
150 BAUD
0
1
0
300 BAUD
1
1
0
1200
BAUD
0
0
1
2400
BAUD
1
0
1
4800
BAUD
0
1
1
9600
BAUD
1
1
1
19200 BAUD
The RS232 Handshake.
____________________
_
DIP switch 4 on switch block 2 is used to select the type
of RS232 handshake required.
Chapter 5
Page 39