3-31
Section 3 • Systems & Components Overview & Operation
370 Outrage
R
Section 3 • Systems & Components Overview & Operation
RESET
TEST
WARN
ING
TEST BEFORE EACH USE
OWER
FAUL
T
ODU
LE
RESET
TEST
WARNING
TEST BEFORE EACH USE
OWER
FAUL
T
ODU
LE
The dual 120V/30A shore power system provides
dockside power to operate all of your boat’s electrical
system and charge your batteries.
Use the supplied 50 ft. power cords to connect your
boat to a dockside power source. The on board
receptacles are located under the aft starboard
gunwale. The AC Main Breaker panel for the shore
power system is located on the starboard wall in the
cabin.
EXTREME HAZARD - Swimming near a boat
operating on an AC electrical system can lead to
severe shock and/or death. Never swim or allow
swimming when AC system is in use.
!
DANGER
Shore Power
Shore Power hookups
Fig. 3.31.2
1
2
ELCI (EQUIPMENT LEAKAGE CIRCUIT
INTERRUPTER)
LINE 1 SHORE POWER MAIN BREAKER
LINE 2 SHORE POWER MAIN BREAKER
DOCKSIDE TV/PHONE INLET
LINE 2 SHORE POWER RECEPTACLE
LINE 1 SHORE POWER RECEPTACLE
3
4
1
2
1
4
5
5
6
3
6
The shore power system on your boat includes an
ELCI (Equipment Leakage Circuit Interrupter)
located on the aft starboard gunnel (See figure
3.30.2).
The ELCI is designed to protect people from line-
to-ground shock hazards which may occur from
defective, misused or neglected electrical equipment.
The ELCI will not prevent line-to-ground electric
shock, but does limit the time of exposure to a
period considered safe for normal healthy persons.
If an imbalance of current is sensed, the ELCI will
trip when the ground fault exceeds 0.030 amps.
This tripping action will occur within a fraction of a
second to prevent serious injury.
ELCI
(Equipment Leakage Circuit Interruptor)
The receptacle will not protect against line-to-
line or line-to-neutral faults, short circuits or
overloads.
!
DANGER
TESTING & TROUBLESHOOTING
TEST BEFORE EACH USE
NORMAL OPERATING STATE
- Sensing
device GREEN LED is ON and circuit breaker
is at ON position.
Step 1
- Press TEST button. GREEN LED
should go OUT and RED LED should come
ON and circuit breaker should trigger to OFF
position.
Step 2 -
If sensing device LED or breaker
does not trip or change state DO NOT USE.
Consult an electrician for assistance.
Step 3
- Press RESET button. The RED LED
should turn OFF and the GREEN LED should
turn ON.
Step 4
- Manually reset (switch) circuit
breaker to ON position to restore circuit
power.
WARNING
IF ABOVE TESTS FAIL,
DO NOT USE
.
CONSULT A QUALIFIED ELECTRICIAN FOR
REPAIR OR REPLACEMENT.
Summary of Contents for 370 Outrage
Page 2: ......
Page 20: ...xx 370 Outrage R THIS PAGE INTENTIONALLY LEFT BLANK...
Page 162: ...4 16 370 Outrage Section 4 Electrical System R Battery Diagram Sheet 1 Fig 4 16 1...
Page 164: ...4 18 370 Outrage Section 4 Electrical System R Helm Breaker Panel Sheet 3 Fig 4 18 1...
Page 168: ...4 22 370 Outrage Section 4 Electrical System R Windlass Schematic Sheet 7 Fig 4 22 1...
Page 170: ...4 24 370 Outrage Section 4 Electrical System R DC Distribution Panel Sheet 9 Fig 4 24 1...
Page 172: ...4 26 370 Outrage Section 4 Electrical System R Hardtop Scematic Sheet 11 Fig 4 26 1...
Page 180: ...4 34 370 Outrage Section 4 Electrical System R Bilge Wiring Schematic Sheet 19 Fig 4 34 1...