7.4.11 Individual
test
The following options can be selected:
Upgrading factory settings
(the latest parameters are transferred from the PC to the appliance)
Statistics
(Only data is read out of the appliance without any change to the
current appliance status)
Configuration of the input diagnostic
(short / long)
(a “short / static” or “long / dynamic” input diagnostic can be selected.
Recommendation = dynamic diagnostic)
Resetting the grinding time
Reset to “initial start up”
(normal = 10 sec./initial start up = 13 sec.)
or keep the current grinding unit running time.
7.4.12 Statistics
The statistical data can be displayed via the individual test.
7.4.13 Output
diagnostic
Customer data from the input diagnostic is saved back in the machine.
(Production, statistical, service, customer data)
Dynamic diagnostic similar to final inspection during production and
input diagnostic, however without external power and temperature
measurement, however with evaporation of the heating cartridge.
Input service entry via input mask (see service stamp)
Identical to the input diagnostic, a report is also prepared here with the
same processing options.
7.4.14 Service
stamp
The service stamp is input via the following form:
7.4.14.1 Group
definition
Specific fault groups are allocated to the working points. When a
working point has been selected, its fault group is activated for
selection in "Input fault code".
A690 = Instantaneous water heater replaced,
4
Fault group
F 4 00 = Coffee water heater blocked
7.4.14.2 Service stamp structure
This concept of the service stamp enables each service centre to
evaluate what work was carried out during the last service and which
faults were rectified. In all 3 service entries are saved in the appliance.
The first stamp is
never
overwritten. In the case of stamps 2 and 3 the
older stamp is overwritten. Therefore it is always obvious when the 2
previous services were carried out.
The definitions as work/fault codes, major faults, employee number
and number of services are included only in the last service entry
in the appliance.
The service date, number of the service centre and invoice item are
saved for all three entries.