58300000111195_ARA_en_f.doc – 02.06.09
Seite 20 von 102
3.6.2.3 Descaling
programme
12.
The appliance is rinsed auto-
matically. Water (approx. 300 ml) is
conveyed in intervals into the drip
tray via the drainage valve.
►
Wait for the next display.
(approx. 4 minutes)
13.
►
Pull drip tray out of the
appliance and empty.
►
Carefully clean contacts of
the drip tray on all sides
and dry.
Ensure that there is no ground
coffee residue or water droplets
between the tray contacts.
►
Re-insert drip tray and
dregs drawer.
14.
The appliance is rinsed auto-
matically.
The descaling process is complete.
The illuminated ring around the
calc
descaling button goes out.
The appliance is ready for use
again.
If the descaling process is termi-
nated prematurely, the descaling
alarm is not cancelled.
3.6.2.4
The descaling programme does not start:
The descaling programme starts only
if the FILTER programming is
not
active.
►
Take the filter out of the water
tank and set the water
hardness.
WARNING!
Never descale the appliance with the filter inserted!
The descaling programme does not
start if the temperature of the heater is
too high.
Symbol flashes 5 x.
►
Cool down the system by
drawing off approx. 1 cup of
hot water.
When the required temperature has
been reached, the descaling process
can be started.