58300000111195_ARA_en_f.doc – 02.06.09
Seite 63 von 102
6.1.3
Greasing the brewing unit
During a service, the O-ring for the coffee outlet
(A)
, the lip seal
surrounding the brewing head
(B)
,
the O-ring for the water inlet
(C)
and the coupling for the input shaft
(D)
must be thinly greased with
food-safe special lubricating grease
PARALIQ® GTE 703 Mat.-no.:
31 0574
.
Note:
After replacing the O-ring for the coffee outlet
(A)
or for
the water inlet
(C)
they must be thinly greased with food-
safe special lubricating grease
PARALIQ® GTE 703
Mat.-no.: 31 0574
.