7-18
Basic parameterization
REFUspeed RS51
DOK-RD500*-RS51*******-IB02-EN-P
Ua
Ub
Uc/d
fa
fb
fc
fd
a
b
c
d
f [Hz]
U [V]
Vboost
Fig. 7-5: V/Hz characteristic diagram
)
.
0117
(
)
.
0120
(
X
P
I
XX
P
R
V
sdrated
S
boost
×
=
Active load monitor WLM
Parame-
ter No.:
Name
Description / explanation
selectable options
Factory setting
min ... max values
Pass
wor
d
0896
ALM sparking sensi-
tivity
1
=
Fixed values
2
=
Analog input 0..±10V
3
=
Analog input 0..+20mA
4
=
Analog input 4..+20mA
5
=
Opt. an.inp 0..±10V (opt. =
optional)
6
=
Opt. an.inp 0..+20mA
7
=
Opt. an.inp. 4..+20mA
8
=
PC (PC with REFUwin via the
service interface)
9
=
Bus SS1
10
=
Bus SS2
11
=
Bus SS4
12
=
Analog input 2..+10V
13
=
Bus SS6
Fixed values
1 ... 13
1
0897
ALM load limit
1
=
Fixed values
2
=
Analog input 0..±10V
3
=
Analog input 0..+20mA
4
=
Analog input 4..+20mA
5
=
Opt. an.inp 0..±10V (opt. =
optional)
6
=
Opt. an.inp 0..+20mA
7
=
Opt. an.inp 4..+20mA
8
=
PC (PC with REFUwin via the
service interface)
9
=
Bus SS1
10
=
Bus SS2
11
=
Bus SS4
12
=
Analog input 2..+10V
13
=
Bus SS6
Fixed values
1 ... 13
1
1203.XX
Fixed value sensitiv-
ity
Supplementary parameter for “fixed values” from
P0896
The appropriate sparking sensitivity is manually set
0.30 %
0.00 ... 100.00 %
1
1216.XX
1)
Fixed value load limit
Supplementary parameter for “fixed values” from
P0897
Sets the corresponding load limit
80.00 %
0.00 ... 190.00 %
1