32/72
Installation
Bosch Rexroth AB
, RE 15300-WA, Version 06.2021
Fig. 26: Articulated connection TC A
1.
The bearing shall be mounted so that the slot in the outer ring is perpendicular
towards the load direction. See
(also valid for
)
2.
The bearing (5) shall be mounted by using a mounting sleeve or tube applied on
the bearing outer ring.
3.
Mount the screws (6) with a tightening torque 47 Nm [34,.67lb ft]
4.
Assemble the rest of the components according to
and
Fig. 27: Electrical isolated articulated connection TC A
1
2
3
5
6
7
8
9
10
11
7
DD00079200
Slot
Fr
DD00079224
Pos Description
Pcs Pos Description
Pcs
1
Linkage part
1
7
Bearing cover
2
2
Fastening support
1
8
Split pin
2
3
Bolt
2
9
Washer (electrical isolated)
4
4
Supporting disc
12
10
Bushing (electrical isolated)
4
5
Spherical plain bearing
2
11
Washer (electrical isolated)
4
6
Countersunk head screw
6