RE 15300-WA, Version 06.2021,
Bosch Rexroth AB
Installation
51/72
Table 17: Oil Volume for lubrication of spline connection
Frame size Horizontal mounted
Vertical mounted
Horizontal mounted Vertical mounted
Litre
US gallon
CBm 2000
14
28
3.7
7.4
CBm 3000
24
48
6.3
12.6
CBm 4000
36
72
9.5
19.0
CBm 5000
44
88
11.6
23.2
CBm 6000
54
108
14.3
28.6
7.4.5 Flange mounting of motor
The splines shall be filled up with hydraulic oil to minimize the risk of wear.
Mounting the motor onto the driven shaft using the assembly tool, see
spline motor to the coupling adapter/driven shaft page 46.
1.
Mount the motor to the flange. For screw dimensions and tightening torque, see
2.
Fill up hydraulic oil to the G 1¼ thread. See
.
Oil volume see
3.
Mount the G 1¼ plug. Torque 180 Nm (133 lbf•ft).
4.
Mount the cover. Torque 200 Nm (148 lbf·ft).
Fig. 52: Flange mounted motor, shaft horizontal
If oil here, it can be used
for the spline. Then take
away the o-ring.
O-ring.
Oil to be filled before
tightening G 1¼ plug.
Plug G 1¼
DD00058221