RE 15300-WA, Version 06.2021,
Bosch Rexroth AB
Installation
55/72
Connection
Description
Dimensions
Remarks
C1
Main connection
2“ *
If C is used as the inlet, the motor shaft rotates clockwise,
viewed from the motor shaft side.
C2, C3, C4, C5, C6
Alternative main
connection
2“ *
Normally plugged at delivery.
A1
Main connection
2“ *
If A is used as the inlet, the motor shaft rotates
counterclockwise, viewed from the motor shaftside.
A2, A3, A4, A5, A6
Alternative main
connection
2“ *
Normally plugged at delivery.
D3
Drain outlet
G 2“
Normally plugged at delivery.
D1, D2, D5, D6
Alternative drain outlets
/ or flushing inlet
G 1 1/4“
Normally plugged at delivery.
D4, D7, D8
Alternative drain outlets
/ or flushing inlet
G 2“
Normally plugged at delivery.
F1, F2
Flushing connections
G 1/4“
For flushing of radial lip seal. Normally plugged.
T1
Test connection
M16 x 2
Used to measure pressure at the main connections.
T2
Test connection
M16 x 2
Used to measure case pressure in housing.
T3
Test connection
G 1/4“
Normally plugged at delivery. T3 can also be used to measure
pressure in the housing by mounting pressure transcducer
R901066595
T4A, T4C
Pressure connection
G 1/2“
Connection for double ended torque arm.
T5
Temperatur sensor
PT100
G 1/4“
Used to measure temperature in the housing.
T6
Alternative test
connection or pressure
connection
G 1/4“
Normally plugged at delivery.
T8
Magnetic plug
1 1/16-12-UN-2B
Used to monitor impurities in the oil.
T7, T9
Alternative magnetic
plug connection
1 1/16-12-UN-2B
Normally plugged at delivery.
*SAE flange J 518 , code 62, 420 bar (6000 psi).
Table 18: Port dimensions