BTV 16/40
PC Box
7-15
DOK-SUPPL*-BTV16/40***-PR02-EN-P
Cross-sections depending
on current consumption,
min. of 4 mm .
For higher current con-
sumption use 2 x 4 mm .
Power supply with
safety transformer
acc.to EN 60742
24 VDC
(1) Easily removable and visible
(2) PE bars should be preferablly installed on the mounting plate
in a conductive manner. In the case of isolated PE bars both
ends must be connected to mounting plate by means of copper
strips with a maximum length of 20 m.
The cross section of the copper strips hast to be, at least, equal
to that of the incoming mains cable.
(3) 0,75 mm up to 6 m
1,5 mm up to 10m
Distances exceeding 10 m require a separate local power supply!
: Terminals in isolated arrangement
10
2
(green/yellow)
(2)
A = Terminal block 4
2
B = Terminal block 10
2
Length max. 4 m
6
2
(1)
(blue)
0 V
24 V
Earth bar
Cross sections depending
on current consumption,
but a min. of 0.5 mm
2
(3)
PE
X10
Power supply
Display with front
keypad and PC
Operator terminal
(24 VDC version)
PE
L2
L3
10
2
(green/yellow)
L1
PE
A
B
A
2
load
load
2
2
2
24V_Trafo.eps
Fig. 7-20:
Wiring of the power connection 24 VDC and the operator terminal
Summary of Contents for Rexroth BTV 16
Page 6: ...IV Contents BTV 16 40 DOK SUPPL BTV16 40 PR02 EN P ...
Page 12: ...1 6 System Presentation BTV 16 40 DOK SUPPL BTV16 40 PR02 EN P ...
Page 66: ...7 20 PC Box BTV 16 40 DOK SUPPL BTV16 40 PR02 EN P ...
Page 94: ...10 6 Ordering Information BTV 16 40 DOK SUPPL BTV16 40 PR02 EN P ...
Page 98: ...11 4 List of Figures BTV 16 40 DOK SUPPL BTV16 40 PR02 EN P ...
Page 109: ......