Bosch Security Systems | 2006-05 | 9922 141 50741 en
Plena Weekly Timer
| Installation and User Instructions | Programming a schedule
en
| 25
table 7.2: Output contact trigger settings
Trigger
settings
Status of event
Status of switch
Example
An event is switched on, and stays
on until switched off.
Closed
A light is switched on
An event is switched off.
Open
After a while, the same
light is switched off
An event is switched on, and then
immediately switched off (pulsed).
Closed, and then
immediately open
A message is started
No event selected.
The
symbol is only used for the
Plena Weekly Timer Configuration
software. If you do not want to select
an event using the display, turn the
rotary selector until no symbol is
displayed.
Open
Nothing happens
Note
The output contacts are Normally Open (NO)
contacts.
Note
When an event is started, the software will set
the output contacts according to the settings of
that current event (and will ignore the settings of
any previous events). For example, if an output
contact that was already open is set to open,
nothing will happen.