background image

Analogue time switch 7 d
Analog-Zeitschaltuhr 7 d
Minuterie analogique 7 d
Interruttore orario analogico 7 d
Interruptor horario analógico 7 d
Interruptor horário analógico 7 d
Analoge schakelklok 7 d

Analogowy zegar sterujący 7 d

TSQW1CO

 

167392

GB

D

F

I

E

P NL PL

Service address/Hotline

Eaton Industries (Austria) GmbH

Scheydgasse 42
A-1215 Wien
www.eaton.com

309518

TSQW1CO

N

L1

L1/L2/L3

16(4) 250

~

1

2

3

TSQW1CO

1910822

110–230V

~       –20T

  50–60Hz

R200h  (230V)

R100h  (110V)

Connection/installation

Warning, danger of death through electric 
shock!

 Must be installed by qualified electrician!

 Disconnect power source!

 Cover or shield any adjacent live components.

 Ensure device cannot be switched on!

 Check power supply is connected!

 Earth and bypass!

 Quarz movement only starts in a few minutes 

    after power is switched on. 

 Full power reserve is achieved after approx.

    5 days.  

WARNING

Klick

45°

8 mm

45°

8 mm

 

 

TSQW1CO

Operating voltage: 

110–230  V~, 50–60 Hz

Power consumption:  

max. 2,5 VA

Switching contact: 

potenzialfrei (not for SELV/PELV)

Contact:  

 

two-way switch

Gap:   

 

<3 mm (µ)

Contact material: 

Ag

Switching capacity: 

16 A, 250 V~, cos 

ϕ

 = 1

 

 

 

4 A, 250 V~, cos 

ϕ

 = 0,6

Incandescent lamp load:  1100 W 
Fluorescent lamp load:  parallel-corrected 2 x 40 W (4,7µF)
Perm. ambient temperature: –20 °C ... +55 °C
Protection class:  

II in accordance with EN 60730-1 for designated installation

Protection rating:  

IP 20 in accordance with EN 60529

Time accuracy: 

 ±1 s/s day at +20 °C

Power reserve: 

R 200 h (230 V), R 100 h (110 V)

Pollution degree:  

2

Type:    

 

1 BSTU

Technical Data

ENGLISH

Description

Œ 

 

Switching pre-selection/manual 

   setting



  

Program timing disc

Ž

  

Switching segments 

  (1 = 2 h)



  

Morning/afternoon 

   (AM/PM) time display



  

Hand for setting time (hours and 

   minutes) can be adjusted 

anti

-

   

clockwise

 and clockwise; turn 

   minute hand firmly to left 

‘

  

Three way switch:

   Permanent ON – AUTO – 
   Permanent OFF

in advance 3:00 ON (= 1)

Set manual operation/
switching pre-selection

Set 1 – 

n

 – 

0 permanent 

switching

Program is not operated. 
1 =   Permanent ON
0 =   Permanent OFF

The time switch operates the set swit-
ching times, i.e. it returns to program.

Connection, technical data see on the back side 

Basic safety instructions

Designated use

• The time switch can be used for lighting, 

  ventilation, fountains, advertising hoardings etc.

• Only for use in closed, dry rooms

• Installation on DIN top hat rail (in accordance 

  with DIN EN 60715)

Disposal

  Dispose of device in environmentally sound 

  manner

Danger of death through electric 

shock or fire!

 Installation should only be carried out 

    by a qualified electrician!

WARNING

Set time

Set day of the week

Set switching times

e.g. mon–fr 10:00–20:00 ON

e.g. 15:00 (afternoon)

e.g. 3:00 (morning)

day (3 = wednesday)

Œ

Ž


‘

n

1

Summary of Contents for TSQW1CO

Page 1: ...m ambient temperature 20 C 55 C Protection class II in accordance with EN 60730 1 for designated installation Protection rating IP 20 in accordance with EN 60529 Time accuracy 1 s s day at 20 C Power...

Page 2: ...oit tre effectu exclusi vement par un lectricien sp cialis AVERTISSEMENT R glage de l heure R glage de jour R glage des horaires de commutation par ex lu ven 10 00 20 00 MARCHE par ex 15 00 d apr s mi...

Page 3: ...realiza las conexiones programadas es decir que regresa al programa ITALIANO ESPA OL Conexi n datos t cnicos v ase el rev s Collegamento dati tecnici vedi il retro Indicaciones b sicas de seguridad Pe...

Page 4: ...hakelklok voert de geprogram meerde schakelingen uit d w z zij keert terug naar het programma PORTUGU S NEDERLANDS Liga o dados t cnicos ver reverso Aansluiting technische gegevens zie achterkant Indi...

Page 5: ...minuti in presenza di tensione La piena riserva di carica si raggiunge dopo 5 giorni AVVERTENZA Klick 45 8 m m 45 8 m m TSQW1CO Tensione d esercizio 110 230 V 50 60 Hz Autoconsumo max 2 5 VA Contatto...

Page 6: ...10 230 V 50 60 Hz Eigen verbruik max 2 5 VA Schakelcontact potentiaalvrij niet voor SELV PELV Contact wisselcontact Openingswijdte 3 mm Contactmateriaal Ag Schakelvermogen 16 A 250 V cos 1 4 A 250 V c...

Page 7: ...enia 2 Typ 1 BSTU Dane techniczne POLSKI Opis Praca r czna wyb r prze czenia Tarcza programu czasowego Segmenty prze cze 1 2 h Wska nik czasu rano po po udniu Wskaz wka ustawienia czasu godziny i minu...

Reviews: