11 | Online Measurement
84 / 120
Modular Sensor Interface MSI 60
Bosch Motorsport
11 Online Measurement
MSI 60
configuration
– System configuration (channel configuration, CAN I/O, PWM Out, etc.) is stored in the
MSI 60.
– Use RaceCon to create and download configuration from the PC to MSI 60
– Communication interface: Ethernet
– Communication protocol: XCP
Online measurement and calibration
– System status and diagnosis
– Check and calibrate sensors in the vehicle.
– Live display of sensor values on the PC
– Use RaceCon for diagnosis, online measurement and calibration.
– Communication interface: Ethernet
– Communication protocol: XCP
11.1 Achieving an online Connection
This chapter describes how to set up the PC for access, going online and how to update
the firmware.
11.1.1 Set up the PC for Access
1.
Switch off local firewall on the PC.
2.
Set IP Configuration for the Ethernet interface to ‘automatic configuration’ (DHCP).
3.
Start RaceCon.
4.
Establish the Ethernet connection to the vehicle.
5.
Power on the vehicle.
6.
Click ‘OK’ to download RaceCon configuration to device.