10 | Analog and Frequency Inputs
72 / 120
Modular Sensor Interface MSI 60
Bosch Motorsport
The third part of the ‘Multipoint Adjustment Wizard’ opens.
a) Physical (channel) value.
b) Electrical (pin) value.
c) Enter physical limits of the sensor.
d) Choose data type of the measurement variable.
e) Enable additonal online calibration.
f) Enter name to automatically create a new measurement sheet.
3.
Click ‘Finish’ when done.
4.
Enter channel name and description.
5.
Click ‘OK’ when done.
The channel is inserted into the MSI 60 Project Tree.
a) Channel is linked to ANA06.
b) Available measurements for channel
c) Input pin pull-up resistor is activated.
d) Multipoint characteristic curve for sensor
e) Adjustment is enabled.
Available measurements for channel
Measurement label
Function
raw_name
mV value of sensor
raw_name_fi
filtered mV value of sensor
name
physical value of sensor
name_fi
filtered physical value