10 | Analog and Frequency Inputs
74 / 120
Modular Sensor Interface MSI 60
Bosch Motorsport
– Filtered signal is delayed with respect to real time signal.
– MSI 60 filters have constant, frequency independent delay.
– Delay (e.g. 22 samples at 10 ms) is corrected during recording.
– No delay filtered vs. unfiltered in recorded data.
– Correction is (of course) not possible for real time data (display, online, PWM out).
– Use filtered data for recording, use unfiltered data for realtime.
10.3.8 Configuring a Frequency Input
Example: Measurement of wheel speed
– Pulse wheel attached to wheel
– Each passing tooth of pulse wheel triggers Hall sensor
– Calculation of wheel speed with wheel circumference
1.
Click on ‘Measurement Sources’ in the Toolbox.
2.
Expand the list of ‘I/O Channels’ by clicking on ‘+’ in the MSI 60 Project Tree.