50
en | Operation
MAP Control Center
F.01U.168.328 | 03 | 2011.05
User guide
Bosch Security Systems, Inc.
The Seismic Test is the same as the Walk Test and uses the same screen, except it only tests
seismic detectors. Seismic detectors equipped with a test transmitter are tested
automatically. Detectors that do not have a test transmitter must be triggered manually. The
Seismic Test can only be carried out if all areas are disarmed.
Print Walk Test
Figure 2.88
Print Walk Test screen
2.8.6
Motion Detector Test
On the Service menu (Figure 2.64, Page 39), press Motion Detector Test. The Motion
Detector Test Select screen (Figure 2.89, Page 50) appears with a green check mark or a red
"X" symbol on the Motion Test All Areas button, indicating:
–
Test mode is On (
), or
–
Test mode is off (
).
Figure 2.89
Motion Detector Test Select screen
To change the symbol on the Motion Test All Areas button, press the button.
To test a selected area (or more than one area), press the Motion Test Selected Area button.
The Motion Detector Test screen appears with red "X" marks (Figure 2.90, Page 51) or green
check marks (Figure 2.91, Page 51).