Product description | FWA 4630 | 31 | en
3 .3
Sensors
3 .3 .1
Fitting and transportation
!
Transport with care.
¶
Avoid impact on the sensors.
¶
Take care not to drop the sensors.
!
The sensors must be in horizontal position on raising
the platform.
i
Heed the notes on commissioning of the sensors
(refer to 1 690 706 006).
1 690 706 006).
).
3 .3 .2
Connection
i
The sensors are assigned by way of the software.
i
There is a difference between left/right sensors. This
can be seen from the marking on the sensor.
1 Camera
2 Reference camera
Fig. 3:
Bottom view of sensor
1 PoE-Switch connection
2 Distributor box connection
3 .3 .3
Important notes on operation
!
Check the sensors for condensation before switch-
ing on.
¶
In the event of moisture, wait for the moisture on the
measuring device to evaporate.
!
The sensors must not be allowed to come into con-
tact with splashwater.
¶
Provide the sensors with a water-proof cover when
cleaning.
!
On the platform the sensor is only to be folded up
for connection and disconnection.
i
Remove the sensors again on completion of mea-
surement.
i
The glass filters of the cameras are to be cleaned
at regular intervals with a clean, soft cloth (e.g. if
contaminated or moist).
3 .4
Plate
Fig. 4:
Plate with plug-in stem
1 Plug-in stem
i
If dirty, clean the plates with warm water containing
a small quantity of detergent (dab only, do not rub
or scour).
i
When in storage, protect the plates against dust
(recommendation: wall bracket for plate and clamp
1690701040