Bosch DAS 3000 S20 Original Instructions Manual Download Page 3

1 689 989 485 | 2020-08-01

Robert Bosch GmbH

1.

Notes on the documenta‐

tion

---Separator---

1.1

Using the documentation

Before commissioning, connecting and using Bosch

products, it is essential to go through the operating in‐

structions – and the safety instructions, in particular –

with great care. By doing so, you can eliminate any un‐

certainties in handling Bosch products and associated

safety risks upfront, which is in the interest of your own

safety and will help avoid damage to the products.

Should a Bosch product be passed on to another per‐

son, the operating instructions with information on its

intended use must be handed over as well.

---

1.2

Symbols used in the documentation

Warning of possible physical damage to the

component or product or of environmental

pollution.

---Separator---

Practical hints, recommendation or reference

to other information.

---Separator---

Warning of danger for the operator during

subsequent procedures.

---Separator---

Single-step procedure.

---Separator---

Optional step.

---Separator---

Result of a procedure.

---Separator---

Reference to a figure. Example: 

 

 12(2)

means figure 12, item 2.

---Separator---

Reference to a page.

---Separator---

1.3

Warnings in the documentation

---Separator---

1.3.1

Meaning of the the signal words

Warnings warn of dangers to the user or people in the

vicinity. The signal word in the warning indicates the

likelihood of occurrence and the severity of the danger

if it is disregarded.

Signal word Likelihood of occur‐

rence

Severity of danger if

disregarded

DANGER

Immediate, imminent

danger

Death or severe injury

WARNING

Possible impending

danger

Death or severe injury

CAUTION

Possible dangerous sit‐

uation

Minor injury

---

1.3.2

Structure of warnings specific to sections

Warnings specific to sections refer to several steps

within a dangerous sequence of actions. Warnings spe‐

cific to sections are placed before a dangerous se‐

quence of actions.

 Signal word

Warning

sign

Type, source and consequences of the

danger.

Measures and instructions to prevent the

danger.

---

1.3.3

Structure of embedded warnings

Embedded warnings refer to an individual dangerous

step. Embedded warnings are placed before a danger‐

ous step. The remedies are embedded in the sequence

of actions.

SIGNAL WORD – type and source of danger. Possi‐

ble consequence if disregarded.

---

2.

Safety

---Separator---

2.1

Safety instructions

The indicator bar as a safety hazard

Magnetic field – The powerful magnets on the indica‐

tor bar may impair the health of people with a pace‐

maker or implanted defibrillator.

People with a pacemaker or implanted defibrillator

must maintain a sufficient distance from the

DAS 3000 S20, especially from the indicator bar.

---

Risk of head impact – The protruding indicator bar at

head height may lead to injury to the head and face.

When working with the DAS 3000 S20, be aware of

the height set for the indicator bar.

Secure the indicator bar in the parked position when

calibrating a front radar sensor.

Secure the indicator bar in the parked position when

the DAS 3000 S20 is not being used.

---

The camera beam and power supply cables as safety

hazards

Tripping hazard – The camera beam protruding at knee

height on the DAS 3000 S20 may lead to tripping re‐

sulting in falls and injury.

Pay attention to the camera beam at knee height.

---

Tripping hazard – Power supply cables at knee height

may lead to tripping resulting in falls and injury.

Use the laptop/tablet on the DAS 3000 S20 in storage

battery mode only.

The laptop/tablet must not be connected to the power

supply cable while work is being carried out with the

DAS 3000 S20.

---

Calibration boards as safety hazards

Falling objects – Incorrectly attached or unsecured cal‐

ibration boards may fall off the DAS 3000 S20, resulting

in minor injury.

Use retaining cables to secure calibration boards with

magnetic attachment.

Remove the calibration board with magnetic attach‐

ment from the indicator bar, and store it in the "Multi-

Target Shop" box when the DAS 3000 S20 is not being

used.

Secure the indicator bar in the parked position when

the DAS 3000 S20 is not being used.

DAS 3000 S20 | 19 | en

Summary of Contents for DAS 3000 S20

Page 1: ...calibrazione e di messa a punto ja 取扱説明書原本の翻訳 キャリブレーションデバイスと調整ユニット lt Originali eksploatacijos instrukcija Kalibravimo ir justavimo įtaisas lv Oriģinālās ekspluatācijas instrukcijas tulkojums Kalibrēšanas un iestatīšanas ierīce nl Oorspronkelijke gebruiksaanwijzing Kalibratie en afstelinrichting no Original driftsinstruks Kalibrerings og justeringsmekanisme pl Oryginalna instrukcja eksploatacji Ur...

Page 2: ...oard CTA 300 x 26 4 11 Installing the reference board CTA 400 x 26 4 12 Installing the Bosch ADAS Positioning soft ware 27 4 13 Installing ADAS Positioning using DDM 27 4 14 Initializing cameras using the QR code 27 5 Operation 27 5 1 Compensating for vertical offset 27 5 2 Attaching the calibration board in vertical posi tions A B or C 28 5 3 Attaching the calibration board in vertical posi tion ...

Page 3: ...f the danger Measures and instructions to prevent the danger 1 3 3 Structure of embedded warnings Embedded warnings refer to an individual dangerous step Embedded warnings are placed before a danger ous step The remedies are embedded in the sequence of actions SIGNAL WORD type and source of danger Possi ble consequence if disregarded 2 Safety Separator 2 1 Safety instructions The indicator bar as ...

Page 4: ...ositioned in front of the vehicle with the aid of the Bosch ADAS Positioning software Diagnostic software such as ESI tronic 2 0 is needed for calibrating advanced driver assistance systems 2 6 Foreseeable misuse Misuse with corresponding intended use The DAS 3000 S20 is pulled or pushed by the edge protection frame to change the position Only use the handles to pull or push the DAS 3000 S20 in or...

Page 5: ...rolling the trolley 3 4 Accessory overview 4712009 02_shd 3 1 2 1 2 4 5 6 6 1 Wheel holder CTA 100 1 2 Reference board CTA 400 1 3 Contact plate CTA 104 1 4 Calibration board 1 681 098 011 CTA 300 1 5 Safety adapter R 6 Mounting adapter 1 3 5 Functional description The following steps must be carried out to calibrate a windshield camera or front radar sensor using the DAS 3000 S20 Attach the calib...

Page 6: ...the bump er 4712009 09_shd 2 1 3 4 1 Wheel holder CTA 100 x on right rear wheel 2 Wheel holder CTA 100 x on left rear wheel 3 Contact plate CTA 104 x on DAS 3000 S20 4 DAS 3000 S20 Step 2 Use Bosch ADAS Positioning to place the DAS 3000 S20 in the required position 4712009 10_shd 2 1 3 4 1 Wheel holder CTA 100 x on right rear wheel 2 Wheel holder CTA 100 x on left rear wheel 3 Contact plate CTA 10...

Page 7: ...t orientation and fastened to the DAS 3000 S20 The camera beam is positioned in the correct orientation when the mini USB ports of the cameras in the camera beam point down wards 1 Position the camera beam 2 so that the mini USB ports 1 of the cameras in the camera beam point downwards 4712005 59_shd 1 1 1 Mini USB ports 2 Position the camera beam 2 with the holes in the T slot above the mountings...

Page 8: ...vertical adjustment of positioning unit 5 Loosen the screws 2 on the offset ruler 1 1 2 2 4712009 16_shd 1 Offset ruler 2 Offset ruler screws 6 Place the 0 point of the offset ruler precisely in the height indicator 2 of the positioning unit 1 1 4712009 18_shd 0 0 1 2 1 2 1 Offset ruler 2 0 point of offset ruler precisely in height indicator of positioning unit 7 Use the screws to secure the offse...

Page 9: ...ulti Target Shop box while it is attached to the trolley 1 2 2 2 4712009 03_shd 1 KTS 560 590 mount 2 Pan head screws ISO 7045 M4 x 6 4 8 Install the USB connecting cables in the camera beam DAS 3000 S20 S20 only 1 Remove the long cover 1 and short cover 2 from the profiled slot 2 Place the USB connecting cables 3 for the CCD cameras in the camera beam in the outer slot of the right vertical profi...

Page 10: ...000 S20 The Multi Target Shop box for safe storage of calibration boards with magnetic attachment is not included in the scope of delivery for the DAS 3000 S20 The box can be placed in and fas tened to the trolley of the DAS 3000 S20 1 Place the Multi Target Shop box 1 in the trolley 2 Secure the box with two knurled screws 2 4712005 40_shd 1 2 2 1 Multi Target Shop box 2 Knurled screws Separator ...

Page 11: ...e camera to the lap top tablet The camera will be initialized The camera image will be displayed 4 Check the serial number on the QR code document to make sure the QR code matches the camera to be initialized 5 Place the included QR code inside the green box in the camera image The camera will be adapted 6 Specify the camera position in Bosch ADAS Positioning The camera is now ready for operation ...

Page 12: ...tioning the calibration board 4 Do not place fingers or hands between the mounting adapter 1 and the bottom edge 2 of the calibra tion board 5 Place the bottom edge of the calibration board 2 in the mounting adapter 1 on the positioning unit 3 1 2 3 4712005 24_shd 1 Mounting adapter 2 Bottom edge of calibration board 3 Positioning unit 6 Push calibration board retainer Z 1 onto the top edge 3 of t...

Page 13: ...that the recess in calibration board retainer Y secures the calibration board 8 Use the knurled screw 6 to hand tighten calibra tion board retainer Y The calibration board is now secured and fixed in place 4712005 27_shd 1 2 3 4 5 6 7 1 Calibration board retainer Z 2 Mounting adapter 3 Bottom edge of calibration board 4 Top edge of calibration board 5 Calibration board retainer Y 6 Knurled screw o...

Page 14: ...icator bar If one of the positioning bars is moved up or down more than 1 cm while the indicator bar is being leveled the inclination of the measurement bay does not allow for the calibration of ad vanced driver assistance systems The measure ment bay is not suitable for calibration 5 5 Attaching the calibration board to the indicator bar The indicator bar is positioned on the frame at the require...

Page 15: ...81 098 011 CTA 300 1 in the parked posi tion 1 Set down calibration board CTA 300 1 3 between the frame and trolley on the edge protection 1 2 Make sure calibration board CTA 300 1 does not trap the USB cable at the bottom of the frame 3 Use safety adapter R 2 to secure calibration board CTA 300 1 3 at the top edge If calibration board CTA 300 1 is not secured in the parked position by safety adap...

Page 16: ...nt hazard from guided brake mechanism 1 Do not place fingers and hands between the brake lever 1 and brake guide 2 2 Operate the brake lever only by means of the handle 3 Pull the handle up slightly and lower the brake along the guide The rubber buffer 3 on the brake contacts the floor and stops the DAS 3000 S20 3 1 2 4712005 32_shd 1 Brake lever 2 Brake guide 3 Rubber buffer on brake Separator 5 ...

Page 17: ...tioning bar 1 686 621 077 Star handle 1x suitable for securing at the R position and Z position 1 686 621 081 T slot nut 2x for the slider 3 842 528 735 Left tape measure for the height of the indica tor bar as viewed from the front 1 687 233 119 Right tape measure for the height of the indi cator bar as viewed from the front 1 687 233 117 Cable carrier 3 842 555 180 Calibration board CTA 300 1 fo...

Page 18: ...rews 2 Magnets Separator 6 5 Replacing slides and end caps of the slide guide on the indicator bar 1 Remove the end cap from the slide guide with the aid of a pliers Make sure that the spring in the end cap does not drop out when the end cap is being removed If the spring drops out and is lost the end cap can no longer be attached to the slide guide 2 Remove the slide with stop from the slide guid...

Page 19: ...st be handed over together with the unit The DAS 3000 S20 is only ever to be transported in the original or equivalent packaging Heed the notes on initial commissioning Separator 7 2 Disposal Dismantle the DAS 3000 S20 and sort out and dis pose of the different materials in accordance with the applicable regulations Separator 8 Technical data Separator 8 1 DAS 3000 S20 specifications Property Spec...

Page 20: ...1 689 989 485 2020 08 01 Robert Bosch GmbH DAS 3000 S20 501 zh Robert Bosch GmbH Franz Oechsle Str 4 73207 Plochingen Deutschland www bosch com bosch prueftechnik bosch com 1 689 989 485 2020 08 01 ...

Reviews: