![Bosch DAS 3000 S20 Original Instructions Manual Download Page 14](http://html.mh-extra.com/html/bosch/das-3000-s20/das-3000-s20_original-instructions-manual_50687014.webp)
1 689 989 485 | 2020-08-01
Robert Bosch GmbH
The mounting adapters are suspended from the han‐
dle and not attached at vertical positions A, B, C or
D.
The height at which the indicator bar is to be posi‐
tioned is known.
---
The required height can be read off the top edge
of the indicator bar. The offset (approx. 15 mm)
from the center of the indicator bar, where the
calibration boards CTA 2xx-x are attached, is al‐
ready taken into consideration in terms of height
adjustment.
1. Press down and hold the locking lever on the indica‐
tor bar.
The safety mechanism will be open so that the in‐
dicator bar can be attached.
CAUTION – Pinch point hazard due to magnetic
force.
2. Do not place fingers or hands between the indicator
bar and the positioning bars.
3. Position the indicator bar at the required height:
— Position the guide pin (2) exactly in front of the T-
slot in the center profile.
— Place the magnets on the indicator bar in front of
the positioning bars on the left and right.
The indicator bar is pulled against the positioning
bars by magnetic force.
The guide pin on the indicator bar is located in
the T-slot of the center profile.
4. Release the locking lever.
The safety mechanism is engaged on the center
profile.
1
2
4712005-29_shd
(1) Locking lever
(2) Guide pin
5. Use the scale on the positioning bars on the left and
right to precisely align the indicator bar at the exact
height.
6. Use the spirit level on the indicator bar to check
whether the DAS 3000 S20 is standing on a level
surface.
— If the spirit level indicates an inclination, use the
spirit level to level the indicator bar.
If one of the positioning bars is moved up or
down more than 1 cm while the indicator bar is
being leveled, the inclination of the measurement
bay does not allow for the calibration of ad‐
vanced driver assistance systems. The measure‐
ment bay is not suitable for calibration.
---
5.5
Attaching the calibration board to the
indicator bar
The indicator bar is positioned on the frame at the
required height.
---
The indicator bar is used for attaching all calibra‐
tion boards CTA 2xx-x to the DAS 3000 S20.
---
If only one Multi-Target-Shop calibration board is
needed for front camera calibration, the board
must be attached to the
left slide
. If the calibra‐
tion board is attached to the right slide, the pat‐
tern on the calibration board will be rotated by
180° and front camera calibration will fail. The
right slide is used only if two Multi-Target-Shop
calibration boards are needed.
1. Pay attention to the mounting pin on the calibration
board and the mounting pin on the slide.
CAUTION – Pinch point hazard due to magnetic
force.
2. Do not place fingers or hands between the indicator
bar and calibration board.
3. Position the calibration board in front of the magnet‐
ic mount on the left slide.
The calibration board will be pulled against the
left slide by magnetic force.
The mounting pin on the calibration board and
the mounting pin on the left slide will engage cor‐
rectly.
4. Attach the retaining cable to a lock ring on the back
of the calibration board.
The calibration board is now secured against fall‐
ing.
---Separator---
5.6
Attaching the contact plate (CTA 104-
x) to the DAS 3000 S20
1. Position the contact plate (CTA 104-x) on the cam‐
era beam with the mounting bracket.
2. Make sure the recesses of the contact plate engage
with the edge of the trolley.
en | 30 | DAS 3000 S20